Size A Pressure Tank

Size A Pressure Tank

NPA GROUP
Sep 17, 2015
  • 2.7 MB

    Dateigröße

  • Android 2.3.2+

    Android OS

Über Size A Pressure Tank

Geben Sie Ihre Daten, um die richtige Größe zu finden Tank.

Since it's inception in 1964, the pre-pressurized potable water tank has assumed various designs and has proven useful in a wide variety of open-system applications. Originally used in well installations, this technology gained widespread acceptance and was soon applied in a variety of applications requiring pressurized water storage. With this flexibility, however, can come confusion as to installation scenarios and related sizing. Below, we'll take a look at proper use and related sizing techniques in such applications as pump cycle control, volume maintenance, and water treatment systems.

Common to the below examples is the fact that it is necessary to determine both the amount of tank storage needed and the pressures necessary to obtain that storage. Simply stated: All sizings use the same principle with different values. Referred to as Boyle's Law of Ideal Gases, this principle will be used to determine how much water is stored in tank at a given pressure. This multiplier will be referred to as the Acceptance Factor. Keep this equation in mind as a foundation to size any pre-pressurized tank:

Pump Systems

It is common knowledge in the water systems industry that cycling a pump motor rapidly will often lead to failure. To prevent this, most pump manufacturers normally recommend a minimum pump runtime of 2 minutes. In order to achieve the runtime, the pre-pressurized tank must store a given volume of water between pump cycles. Doing so requires the pump to run for a specific period to fill the tank. In general, larger pumps require longer intervals between start cycles. When sizing a pre pressurized tank for the above purpose, the following information should be known: Pump horsepower, pump output in gallons per minute ( GPM ), and pressure switch setting in psi (cut-in & cut-out). The below procedure will guide you through a sizing scenario using a 1hp pump. The pump will be operating at 15 GPM with a pressure switch setting of 40psi cut-in and 60psi cut-out. The Acceptance Factors have already been calculated in the chart provided. The figures are based on a tank precharge (initial air charge) set 2psi below pump cut-in pressure.

According to the "Recommended Minimum Runtime" notation, a 1hp pump should operate for a period of at least 2 minutes between motor starts. In order to run a 15GPM pump for 2 minutes, 30 gallons of storage is necessary. The Acceptance Factor indicates that 27% of a given tank's volume will be usable water between 40 and 60psi. Dividing 30 by an acceptance factor of .27 results in a tank with a volume of 111 gallons.

Mehr anzeigen

What's new in the latest 2.1

Last updated on Sep 17, 2015
Minor bug fixes and improvements. Install or update to the newest version to check it out!
Mehr anzeigen

Videos und Screenshots

  • Size A Pressure Tank Plakat
  • Size A Pressure Tank Screenshot 1
  • Size A Pressure Tank Screenshot 2
  • Size A Pressure Tank Screenshot 3
  • Size A Pressure Tank Screenshot 4

Size A Pressure Tank APK -Informationen

Letzte Version
2.1
Kategorie
Lernen
Android OS
Android 2.3.2+
Dateigröße
2.7 MB
Entwickler
NPA GROUP
Sichere und schnelle APK-Downloads auf APKPure
Mit APKPure können Sie Size A Pressure Tank APK einfach und sicher mit Signaturüberprüfung herunterladen.

Alte Versionen von Size A Pressure Tank

APKPure Zeichen

Superschnelles und sicheres Herunterladen über die APKPure-App

Ein Klick zur Installation von XAPK/APK-Dateien auf Android!

Download APKPure
thank icon
We use cookies and other technologies on this website to enhance your user experience.
By clicking any link on this page you are giving your consent to our Privacy Policy and Cookies Policy.
Learn More about Policies