공기 심리 측정 및 증발 냉각을위한 최고의 응용 프로그램!

The ultimate app for air psychometrics and evaporative cooling!

What are the air characteristics given the current values of temperature and humidity? How can I calculate the mix of two air stream? What is the humidification load for my AHU? These are some of the questions this app can provide answers for, and, on top, also estimates of power saved by evaporative cooling.

There are 9 functions available inside the app:

· AIR calculates the characteristic parameters of the air by entering 2 of the following 4 values: dry-bulb temperature (DBT), wet-bulb temperature (WBT), %rh, humidity ratio. The outputs are: dew-point temperature, specific enthalpy, density, specific volume, vapor pressure, vapor density

· MIX calculates the characteristics of the mixture from the properties of two air streams (DBT, WBT, %rh, W, flow rate)

· HUMIDIFICATION LOAD 1 calculates the humidification load based on an air current upstream of the humidifier and a set point. The outputs are: the humidification load, the flow rate of the atomized water (only in the case of adiabatic humidification) and the conditions of pre-heating

· HUMIDIFICATION LOAD MIX calculates the humidification load from the mixture of 2 air streams upstream of the humidifier and a set point. The outputs are: the humidification load, the flow rate of the atomized water (only in the case of adiabatic humidification), the conditions of pre-heating, the characteristics of the mixture of the two air streams upstream of the humidifier

· DEC (Direct Evaporative Cooling) calculates the cooling, as temperature and as power, of an air stream by the evaporation of water sprayed in it

· IEC (Indirect Evaporative Cooling) calculates the cooling, as temperature and as power, of a primary air stream by evaporation of water sprayed in a secondary air stream that does NOT mix with the primary stream. The primary and secondary streams pass through a cross-flow heat exchanger

· DEC + IEC calculates the cooling, as temperature and as power, of a primary air stream by evaporation of water sprayed both in the primary stream and in a secondary air stream. The primary and secondary streams pass through a cross-flow heat exchanger WITHOUT mixing. The secondary stream is the exhausted part of the return air. If the exhaust flow is less than the primary flow, the part of return air not exhausted is mixed with the cooled primary air after the heat exchanger.

· EVAPORATIVE COOLING calculates the additional heat rejected by a condenser coil/dry cooler when they are sprayed by water, assuming that water completely wets the exposed surface of the heat-rejection coil.

· AFTER THE AIR HUMIDIFIER IN AHU/DUCT calculates the conditions downstream of the humidifier in AHU/duct once the environment’s set point and internal sensible and latent loads are entered.

더 보기

What's new in the latest 4.1

Last updated on 2015-11-02
- new ebooks request form
더 보기

비디오 및 스크린 샷

  • Climate tools 포스터
  • Climate tools 스크린샷 1
  • Climate tools 스크린샷 2
  • Climate tools 스크린샷 3
  • Climate tools 스크린샷 4

Climate tools의 오래된 버전

APKPure 아이콘

APKPure 앱을통한매우빠르고안전한다운로드

한번의클릭으로 Android에 XAPK/APK 파일을설치할수있습니다!

다운로드 APKPure
thank icon
사용자 환경을 개선하기 위해 이 웹 사이트의 쿠키 및 기타 기술을 사용합니다.
이 페이지의 링크를 클릭하면 당사의 개인 정보 보호 정책쿠키 정책에 동의하는 것입니다.
더 알아보기