About 導線安培容量
Can quickly check the wire ampere capacity.
[Important!! Maintenance updates are suspended!!]
Since Microsoft's support for Xamarin ends on 2024.05.01, versions after Android 14 are not guaranteed to function properly.
-------------------------------------------------- ----------------------------------
※ Based on the latest Taiwan regulations [Regulations on User Electrical Equipment Installation] released on 2021.03.17
[Rules for Installation of User Electrical Equipment] (original name: Rules for House Wiring Installation or Electrical Regulations)
Chapter 1 General Principles
Section 6 Ampere Capacity
Article 16
The ampere capacity of low-voltage insulated wires, single-core and multi-core insulated cables shall comply with the following requirements:
1. The allowable temperature of wire insulation is specified in Table 16-1.
2. For metal conduit wiring, the ampere capacity shall be selected in accordance with Table 16-3, Table 16-4 and Table 16-6. The same applies to the ampere capacity of metal flexible conduit wiring.
3. The ampere capacity of PVC pipe wiring shall be selected in accordance with Table 16-7. The ampere capacity of HDPE pipe wiring and non-metallic flexible conduit wiring is also the same.
4. For insulated cables with more than 10 current-carrying conductors or more than 10 cores of current-carrying conductors installed in the same conduit, the ampere capacity should be multiplied by the correction factor in Table 16-8.
5. Insulated wires do not include neutral wires, ground wires, control wires and signal wires. However, if there is harmonic current in the neutral line of a single-phase three-wire or three-phase four-wire circuit, it should be regarded as a current-carrying conductor and be included in the calculation.
6. When insulated conductors are installed in places where the ambient temperature is higher than 35°C, their ampere capacity should be multiplied by the correction factor listed in Table 16-9.
This software can quickly query Table 16-6 and Table 16-7.
◆ Disclaimer
1. The program developer does not guarantee the content of this program and the information provided in the calculation results.
2. The program developer is not responsible for any damage, disadvantage or trouble caused to users or third parties by using this program or its calculation results.